Data Center Standards Sample Clauses

Data Center Standards. Contractor’s Data Centers shall have fully redundant and diverse network paths to City endpoints. Data Centers shall be located in geographically different seismic zones characterized by the lowest predicted chance of damage as defined by the US Geological Survey Earthquake Hazards Program. Environmental systems must monitor/detect temperature, humidity, fluid leaks, fire/smoke/particulate and have accompanying suppression systems. Fire suppression systems should be dry pipe. Power should be fully conditioned to avoid spikes and other aberrations that can damage equipment. Temporary power units, such as generators, must be in place to support SaaS Services in the event of a power outage for up to three calendar days, and fuel replenishment contracts must be in place to keep temporary power operational for longer periods.
Data Center Standards. Contractor’s Data Centers have fully redundant and diverse network paths to City endpoints. Data Centers shall be located in geographically different seismic zones characterized by the lowest predicted chance of damage as defined by the US Geological Survey Earthquake Hazards Program. Only authorized personnel may access the Data Centers using at least two-factor authentication. Video surveillance systems must record all movements, 24 hours a day, inside and outside the perimeter of the Data Centers. Environmental systems must monitor/detect temperature, humidity, fluid leaks, fire/smoke/particulate and have accompanying suppression systems. Fire suppression systems should be dry pipe. Power should be fully conditioned to avoid spikes and other aberrations that can damage equipment. Temporary power units, such as generators, must be in place to support Hosted Services in the event of a power outage for up to three calendar days, and fuel replenishment contracts must be in place to keep temporary power operational for longer periods.
Data Center Standards. The Contractor shall be responsible for all fees and costs associated with the hosting of the XX.xxx Web Portal at a primary facility with a secondary site with “warm” backup capabilities for non-critical systems and “hot” backup capabilities for critical systems at a location in the United States that is geographically remote from the primary site in or an Azure or Amazon Infrastructure as a service (IaaS), Platform as a Service (PaaS) or Software as a Service (SaaS) environment also at a location in the United States, or a hybrid solution. The Contractor and its proposed Data Center vendor (if applicable) are responsible for all hardware, network infrastructure, security infrastructure, server infrastructure, disaster recovery infrastructure and related tools and utilities necessary to support a web portal of this size and complexity. The following represents key facets of the typical infrastructure required: ● Web Servers: 16 virtual servers (Production), 4 virtual servers (Test). This is subject to load, with the ability to ramp up if needed. o Applications servers are not included in this number, which is approximately 300 and growing. ● Load Balancers: 4 physical with additional virtual capability (2 physical appliances in each data center) ● Server Management Software and Tools Licensing: ● SQL Server Databases: 1 Development, 2 Quality Assurance (QA), 4 Production in a multi data center cluster. ● Additional Database: 1 Production Cluster hosted by the Contractor. IOT shall host the Production and Test Instance for XX.xxx. ● Intrusion Prevention System ● Multi-Node Web Application Firewall ● File Upload Scanning Appliance ● Security Event and Incident Management (XXXX) Logging Tool o At the State’s request, the parties will explore options for the XXXX to be interfaced to the State’s security logging tool ● Logging Software ● Virtual Hosts: 10 Hosts spread across two data centers ● EMC Storage: Multiple Storage Arrays split between two data centers ● Firewalls and Switches ● Internet Bandwidth supports 2Gbps and above in multiple data centers ● DDOS appliances in both data centers ● VPN connecting the primary vendor datacenter with the IOT datacenter

Related to Data Center Standards

  • OMB Standards Unless specified otherwise within this agreement, the Subrecipient shall procure all materials, property, or services in accordance with the requirements of 24 CFR 84.40−48.

  • Contractor Standards Contractor shall comply with Contractor Standards provisions codified in the SDMC. Contractor understands and agrees that violation of Contractor Standards may be considered a material breach of the Contract and may result in Contract termination, debarment, and other sanctions.

  • Safety Standards Performance of the Contract for all commodities or contractual services must comply with requirements of the Occupational Safety and Health Act and other applicable State of Florida and federal requirements.

  • Applicable Standards The requirements and guidelines of NERC, the Applicable Regional Entity, and the Control Area in which the Customer Facility is electrically located; the PJM Manuals; and Applicable Technical Requirements and Standards.

  • Quality Standards Each Party agrees that the nature and quality of its products and services supplied in connection with the other Party's Marks will conform to quality standards set by the other Party. Each Party agrees to supply the other Party, upon request, with a reasonable number of samples of any Materials publicly disseminated by such Party which utilize the other Party's Marks. Each Party will comply with all applicable laws, regulations, and customs and obtain any required government approvals pertaining to use of the other Party's marks.

  • Security Standards The Provider shall implement and maintain commercially reasonable security procedures and practices that otherwise meet or exceed industry standards designed to protect Student Data from unauthorized access, destruction, use, modification, or disclosure, including but not limited to the unauthorized acquisition of computerized data that compromises the security, confidentiality, or integrity of the Student Data (a "Security Breach"). For purposes of the DPA and this Exhibit G, "Security Breach" does not include the good faith acquisition of Student Data by an employee or agent of the Provider or LEA for a legitimate educational or administrative purpose of the Provider or LEA, so long as the Student Data is used solely for purposes permitted by SOPPA and other applicable law, and so long as the Student Data is restricted from further unauthorized disclosure.

  • Information Technology Accessibility Standards Any information technology related products or services purchased, used or maintained through this Grant must be compatible with the principles and goals contained in the Electronic and Information Technology Accessibility Standards adopted by the Architectural and Transportation Barriers Compliance Board under Section 508 of the federal Rehabilitation Act of 1973 (29 U.S.C. §794d), as amended. The federal Electronic and Information Technology Accessibility Standards can be found at: xxxx://xxx.xxxxxx-xxxxx.xxx/508.htm.

  • Health and Safety Standards Contractor shall abide by all health and safety standards set forth by the State of California and/or the County of Xxxxxx pursuant to the Injury and Illness Prevention Program. If applicable, Contractor must receive all health and safety information and training from County.

  • Compliance with Accessibility Standards All parties to this Agreement shall ensure that the plans for and the construction of all projects subject to this Agreement are in compliance with standards issued or approved by the Texas Department of Licensing and Regulation (TDLR) as meeting or consistent with minimum accessibility requirements of the Americans with Disabilities Act (P.L. 101-336) (ADA).

  • Property Standards Owner must maintain the Unit, and any common areas of the property accessible to the Tenant under the Lease, in decent, safe and sanitary condition and comply with all applicable state or local codes and requirements for rental properties. Upon notice by the Program Administrator following any inspection (whether conducted in-person or virtually in accordance with the Program guidelines), Owner will promptly correct any violations of Program requirements and this Contract. If the Owner fails to correct such violations, the Program Administrator may terminate this Contract and the Rental Assistance Payment even if the Tenant continues occupancy under the Lease. Owner/Representative Initials: